IJSRSET calls volunteers interested to contribute towards the scientific development in the field of Science, Engineering and Technology

Home > IJSRSET1173133                                                     


Detection Of Partial Discharge Activity In H.V Rotating Equipment

Authors(1):

Hitesh B. Renuka
  • Abstract
  • Authors
  • Keywords
  • References
  • Details
Insulation property play important role in h.v rotating machine. Detection and monitoring of partial discharge activity gives a information about quality of insulation. It gives a indication of insulation deterioration. Partial discharge detect the points of degradation of insulation. (i) HFCT (ii) HVCC (iii) TEV (iv) Rogowski Coil(RC) sensor are used for detection and monitoring of partial discharge activity. By using this sensors PD activity detect and monitor the condition of insulation of the machine without interrupting the running of machine.

Hitesh B. Renuka

Partial discharge, motors, on line partial discharge, high frequency current transformer, HFCT, high voltage coupling capacitor, HVCC, Partial discharge testing, PD monitoring.

  1. Malcolm Seltzer, Klaus Winter, Ross Mackinlay, Lee Renforth, “On-Line Partial Detection And Control on MV Cable Network with Ground Fault Neutralizer”, 22nd International conference on electric distribution, paper 1339, Stockholm.
  2. Claude Kane, Stephen V.Carney, Igor Blokhintsev, John Pozonsky, “Adavantage of Continuous Monitoring of Partial Discharge in Rotating Equipment and Switchgear” IEEE.
  3. Lee Renforth, Steven Goodfellow, David Clark, Rogger Shuttleworth, “Remote Monitoring of Partial Discharge Activity within High-Voltage Rotating Machine in Hazardous Locations”, IEEE.
  4. Lee Renforth, Russell Armstrong, David Clark, Steven Goodfellow, Paul.S.Hamer, “ A Technique For The Remote Partial Discharge Monitoring Of The Stator Insulation Of High Voltage Motors Located In Hazardous Locations”, IEEE Paper No.PCIC
  5. Lee Renforth, Paul.S.Hamer, David Clark, Steven Goodfellow, Rodney Tower, “Continuous, Remote On-Line Partial Discharge(OLPD) Monitoring Of Hv Ex/Atex Moters In The Oil And Gas Industries”, IEEE Paper No,PCIC 2013.
  6. hvpd.co.uk

Publication Details

Published in : Volume 3 | Issue 1 | January-February - 2017
Date of Publication Print ISSN Online ISSN
2017-02-28 2395-1990 2394-4099
Page(s) Manuscript Number   Publisher
140-143 IJSRSET1173133   Technoscience Academy

Cite This Article

Hitesh B. Renuka, "Detection Of Partial Discharge Activity In H.V Rotating Equipment", International Journal of Scientific Research in Science, Engineering and Technology(IJSRSET), Print ISSN : 2395-1990, Online ISSN : 2394-4099, Volume 3, Issue 1, pp.140-143, January-February-2017.
URL : http://ijsrset.com/IJSRSET1173133.php