Modeling of Patient of Type 1 Diabetes for Blood Glucose Control

Authors(2) :-Divya K Nadar, Jimit A Talati

The recent development in the insulin delivery system is the automatic one .The blood glucose levels are controlled by the feedback loop. The initial success with the simple models in normalizing blood glucose level led to the improvement of the devices including variety of control system. The insulin delivery system to diabetic is a tedious job and doesn’t ensure proper performance and leads to various complications if the delivery of insulin is not proper. The system which is a portable one used to control the blood glucose concentration. In this paper theoretical analysis has been performed to regulate blood glucose insulin concentration on the basis of some mathematical models. The closed-loop insulin delivery system is composed of three essential components: a stable glucose sensor for measuring the glucose concentration, a control system regulating external insulin infusion based on the glucose-insulin system and a safe and stable insulin pump.

The goal is to control and analyze two controllers which were designed to control the plant which is diabetic patient for this paper and the controllers analyzed are proportional integral derivative (PID), and fuzzy logic controllers (FLC). Mathematical modeling of a patient is shown in this paper. Simulation would be performed in MATLAB software.

Authors and Affiliations

Divya K Nadar
Department of Instrumentation and Control, Gujarat Technological University, Rajkot, Gujarat, India
Jimit A Talati
Department of Instrumentation and Control, Gujarat Technological University, Rajkot, Gujarat, India

PID, Fuzzy Control, Type 1 Diabetes, Modeling of Diabetic Patient.

  1. Polonsky KS (2012). "The Past 200 Years in Diabetes". New England Journal of Medicine
  2. Saydah SH, Miret M, Sung J, Varas C, Gause D, Brancati FL "Postchallenge hyperglycemia and mortality in a national sample of U.S. adults". Diabetes Care  (8): 1397–402. August 2001
  3. Srinivas, P., and P. Durga Prasada Rao. "CLOSED LOOP MODEL FOR GLUCOSE INSULIN REGULATION SYSTEM USING LABVIEW.".
  4. Sorensen, John Thomas. “A physiologic model of glucose metabolism in man and its use to design and assess improved insulin therapies for diabetes”. Diss. Massachusetts Institute of Technology, 1985.
  5. Parker, Robert S., et al. "Robust H~∞ Glucose Control in Diabetes Using a Physiological Model." AIChE Journal 46.12  (2000): 2537-2549.

Publication Details

Published in : Volume 2 | Issue 1 | January-February 2016
Date of Publication : 2016-02-25
License:  This work is licensed under a Creative Commons Attribution 4.0 International License.
Page(s) : 336-340
Manuscript Number : IJSRSET162183
Publisher : Technoscience Academy

Print ISSN : 2395-1990, Online ISSN : 2394-4099

Cite This Article :

Divya K Nadar, Jimit A Talati, " Modeling of Patient of Type 1 Diabetes for Blood Glucose Control, International Journal of Scientific Research in Science, Engineering and Technology(IJSRSET), Print ISSN : 2395-1990, Online ISSN : 2394-4099, Volume 2, Issue 1, pp.336-340, January-February-2016.
Journal URL : http://ijsrset.com/IJSRSET162183

Follow Us

Contact Us