Chiller and AHU Design for A commercial Usage

Authors(5) :-S M Azfar Hashmi, Mirza Muneer Baig, M A Kabeer, Syed Faraz Abdullah, Mohd Saber

Central air conditioning is more reliable for easy operation with a lower maintenance cost. The effective design of central air conditioning can provide lower power consumption; low capital cost and improves aesthetics of a building. This paper establishes the results of cooling load calculation under different climate conditions by using HAP for a commercial building1. Heating and cooling due to people, lighting, infiltration, ventilation, and cooling load due to walls and roofs. Using ASHRAE and CARRIER Fundamental Hand Books. And here the study of air water vapor mixture, (called psychometrics) for human comfort in the air conditioning system for the city Hyderabad.

Authors and Affiliations

S M Azfar Hashmi
Department of Mechanica Engineering, Lords Institute of Engineering & Technology, Hyderabad, Telangana, India
Mirza Muneer Baig
Department of Mechanica Engineering, Lords Institute of Engineering & Technology, Hyderabad, Telangana, India
M A Kabeer
Department of Mechanica Engineering, Lords Institute of Engineering & Technology, Hyderabad, Telangana, India
Syed Faraz Abdullah
Department of Mechanica Engineering, Lords Institute of Engineering & Technology, Hyderabad, Telangana, India
Mohd Saber

Hourly Analysis Programme, Cubic Feet per Minute, Static Pressure, Gallons per minute, Head Loss of Chilled Water Pump.

  1. Milne, M, et al., “Climate Consultant 40 Develops Design Guidelines for Each Unique Climate, “proceedings of the American Solar Society. Buffalo New York, 2009.
  2. Givoni, b., Man Climate and Architecture, Van Nostrand Reinhold, 1981.
  3. Givoni, B., Climate Considerations in building and Urban Design. John Wiley and Sons, New York, 1998.
  4. Driscoll, M. P., Psychology of learning for Instruction. Pearson Education, Florida State University, 2005.
  5. “Fundamentals of HVACR “ by Carter Stanfield, David Skaves 2009

Publication Details

Published in : Volume 3 | Issue 2 | March-April 2017
Date of Publication : 2017-04-30
License:  This work is licensed under a Creative Commons Attribution 4.0 International License.
Page(s) : 699-704
Manuscript Number : IJSRSET1732193
Publisher : Technoscience Academy

Print ISSN : 2395-1990, Online ISSN : 2394-4099

Cite This Article :

S M Azfar Hashmi, Mirza Muneer Baig, M A Kabeer, Syed Faraz Abdullah, Mohd Saber, " Chiller and AHU Design for A commercial Usage, International Journal of Scientific Research in Science, Engineering and Technology(IJSRSET), Print ISSN : 2395-1990, Online ISSN : 2394-4099, Volume 3, Issue 2, pp.699-704, March-April-2017. Citation Detection and Elimination     |     
Journal URL : https://ijsrset.com/IJSRSET1732193

Article Preview