Design of R.C.C Overhead Water Tank

Authors

  • Roshan Y. Gawarle  Civil Engineering Department, Tulsiramji Gaikwad-Patil College of Engineering & Technology, Mohgaon, Nagpur, Maharashtra, India
  • Palash A. Wagh  Civil Engineering Department, Tulsiramji Gaikwad-Patil College of Engineering & Technology, Mohgaon, Nagpur, Maharashtra, India
  • Himani Dakare  Civil Engineering Department, Tulsiramji Gaikwad-Patil College of Engineering & Technology, Mohgaon, Nagpur, Maharashtra, India
  • Naina Dokare  Civil Engineering Department, Tulsiramji Gaikwad-Patil College of Engineering & Technology, Mohgaon, Nagpur, Maharashtra, India
  • Shankumar Kummari  Civil Engineering Department, Tulsiramji Gaikwad-Patil College of Engineering & Technology, Mohgaon, Nagpur, Maharashtra, India
  • Dhanashree Sawarbandhe  Civil Engineering Department, Tulsiramji Gaikwad-Patil College of Engineering & Technology, Mohgaon, Nagpur, Maharashtra, India

Keywords:

Economical Design, IS-3370:2009, Limit State Method, IS-456:2000, Circular Overhead Tank

Abstract

The water tank is used to store water to tide over the daily requirements. Water tanks can be of different capacity depending upon the demand requirement of a municipal corporation. water which covers about 71% of the earth surface. This paper gives an overall designing procedure of an Overhead Circular tank using LIMIT STATE METHOD from IS-3370:2009. the crack width was also checked by a limit state of serviceability IS-3370: 2009. It was observed that in case of limit state design cost required is less. Obviously, the circular water tank is more economical compared to the square tank. This paper gives, the theory behind the design of a liquid retaining structure, Elevated circular water tank with a domed roof, circular wall, top ring beam, flat base slab, and bottom beam are design with limit state method.

References

  1. Asati Ankush N., KaduMahendra S. (2014),"Seismic investigation of RC elevated water tank for different types of staging patterns"
  2. Bhandari M, Singh Karan Deep (2014),"Comparative study of design of water tank"
  3. Bhandari M, Singh Karan Deep (2014),"Economic design of water tank of different shapes"
  4. Dixit B Patel. Patel. Chirag. N. (2016), "A review on overhead water tank staging considering Fluid-Structure-Soil Interaction"
  5. Dona Rose K J, Sreekumar M, Anumod A S (2015), "A study of overhead water tanks subjected to dynamic loads"
  6. Kagdelwar Bhagyashree Prakash, Patil A. V.(2016), "Economic design of RC elevated water tanks by using IS 3370 and its revision is 3370 (2009)"
  7. J. Yogeshwarana, C.Pavithra,(2015), "Behaviour of an elevated RC tank subjected to various earthquake responses"
  8. Young-MyungYang, Ji-Hoon Kim, Heung-SeokSeo, Kangwon Lee, Ihn-Soo Yoon (2006),"Development of the world’s largest above-ground full containment storage tank"
  9. Munshi J.A. and Sherman W.C., ‘ Reinforced concrete tanks’pg.101-108, Feb2004, Concrete International Journal.
  10. Ashok K. Jain, ‘Reinforced concrete Limit State Design’, pg.196-197, pg.671-677, Nem Chand & Bros., Roorkee 247 667,India.

Downloads

Published

2019-03-16

Issue

Section

Research Articles

How to Cite

[1]
Roshan Y. Gawarle, Palash A. Wagh, Himani Dakare, Naina Dokare, Shankumar Kummari, Dhanashree Sawarbandhe, " Design of R.C.C Overhead Water Tank, International Journal of Scientific Research in Science, Engineering and Technology(IJSRSET), Print ISSN : 2395-1990, Online ISSN : 2394-4099, Volume 5, Issue 6, pp.257-263, March-2019.