Structural Audit of 40 year old Silo

Authors

  • Akshay Shivankar  PG Student, Structural Engineering, G H Raisoni College of Engineering, Nagpur, India
  • Dr. K. R. Dabhekar  Asst Professor, Civil Engineering Department, G H Raisoni College of Engineering Nagpur, India
  • P. B. Patil  Asst Professor, Civil Engineering Department, G H Raisoni College of Engineering Nagpur, India
  • Dr. I. P. Khedikar  Asst Professor, Civil Engineering Department, G H Raisoni College of Engineering Nagpur, India
  • Dr. D. P. Mase  Director of P T MASE & ASSOCIATES, Nagpur, Maharashtra India

DOI:

https://doi.org/10.32628/IJSRSET218260

Keywords:

PH test, Half-cell test, Ultrasonic pulse velocity test, Rebound hammer test, NDT method, Structural Assessment Program

Abstract

In India structural stability of old structures and fire protection and safety is one of the most common issues. because the strength of old structures get reduced in due course of your time it generate structural flaws like material diminution, unexpected over loading, structural scarcity or physical damages and if further use of such damaged structure it's getting to leads to severe loss of human life and public property. As Structural Audit of old structure is obligatory as per municipal authorities and Government of Gujarat has made "Structural Audit" of all old structures compulsory. the most objective of present work is to adopt Structural Auditing of 40 years old silo which is situated at Somnath (Gujrat) with Schmidt’s Hammer Test, Ultra Sonic Pulse Velocity Test, Cover Meter Test, Half-cell test, pH test including Visual Inspection and assessing the stableness and safety of the structure to confront to for its remaining life by diagnosis and root explanation for the issues with remedial measures. Based upon above test is observed that the attribute of concrete is medium at maximum locations and Doubtful at few locations, corrosion has started in reinforcement and well within the suitable limit. Hence, it's recommended to repair damaged areas as per the methodology, specifications and locations.

References

  1. Nondestructive testing of concrete method of test (Ultra Sonic Pulse Velocity) IS 13311 (Part I) 1992
  2. Schmidt hammer IS 13311 (Part II) 1992
  3. Code of practice for reinforced concrete IS 456-2000
  4. Method of tests for strength of concrete IS 516-1959
  5. Strength evaluation of existing concrete building report by ACI committee 437 ACI-437R-91
  6. Corrosion of metal in concrete Part I report by ACI committee 222 ACI-222R-89
  7. pH value B.S. 5741-1991
  8. Dr. Dilip P. Mase, A Case Study of Structural Assessment and  Auditing report for Residential Building Nagpur (Maharashtra),  August 2018.
  9. BS 1881: Part 201: 1986 British Standard Testing concrete Part 201. Guide to the use of nondestructive methods of test for hardened concrete.

Downloads

Published

2021-04-30

Issue

Section

Research Articles

How to Cite

[1]
Akshay Shivankar, Dr. K. R. Dabhekar, P. B. Patil, Dr. I. P. Khedikar, Dr. D. P. Mase "Structural Audit of 40 year old Silo" International Journal of Scientific Research in Science, Engineering and Technology (IJSRSET), Print ISSN : 2395-1990, Online ISSN : 2394-4099, Volume 8, Issue 2, pp.222-230, November-December-2021. Available at doi : https://doi.org/10.32628/IJSRSET218260