ON-Grid Hybrid Multi-Input Transformer Coupled Bidirectional DC-DC Converter with Multilevel Inverter

Authors

  • Prasanna Lakshmi Bukke   Siddartha Institute of Engineering and Technology(SIET), Hyderabad , Telangana, India

Keywords:

: Torque controlled configuration, multi level inverter, D-q model, six-phase induction motor.

Abstract

This paper presents a configuration with structure electrical converter with six-phase induction motor, this configuration proposes force management of 2 pole induction motor in rotating system. The model is simulated in Simulink atmosphere to guage its performance beneath load and no-load conditions. The results show reliable and smart performance of the motor. Total circuit is simulated in MATLAB simulink.

References

  1. F.Valenciaga and P. F. Puleston, "Supervisor control for a stand-alone hybrid generation system using wind and photovoltaic energy," IEEE Trans. Energy Convers., vol. 20, no. 2, pp. 398-405, Jun. 2005.
  2. C. Liu, K. T. Chau and X. Zhang,"An efficient wind-photovoltaic hybrid generation system using doubly excited permanent-magnet brushless machine,"IEEE Trans. Ind. Electron., vol. 57, no. 3, pp. 831-839, Mar.2010.
  3. W. Qi, J. Liu, X. Chen, and P. D. Christofides, "Supervisory predictive control of standalone wind/solar energy generation systems," IEEE Trans. Control Sys. Tech., vol. 19, no. 1, pp. 199-207, Jan. 2011.
  4. F. Giraud and Z. M. Salameh, "Steady-state performance of a grid connected rooftop hybrid wind-photovoltaic power system with battery storage," IEEE Trans. Energy Convers., vol. 16, no. 1, pp. 1-7, Mar. 2001.
  5. S. K. Kim, J. H. Jeon, C. H. Cho, J. B. Ahn, and S. H. Kwon, "Dynamic modeling and control of a grid-connected hybrid generation system with versatile power transfer, "IEEE Trans. Ind. Electron., vol. 55, no. 4, pp. 1677-1688, Apr. 2008.
  6. M. Dali, J. Belhadj and X. Roboam, "Hybrid solar-wind system with battery storage operating in grid-connected and standalone mode: control and energy management-experimental investigation," Energy, vol. 35, no. 6, pp. 2587-2595, June 2010.
  7. W. Kellogg, M. Nehrir, G. Venkataramanan, and V. Gerez, "Generation unit sizing and cost analysis for stand-alone wind, photovoltaic and hybrid wind/PV systems, "IEEE Trans. Ind. Electron., vol. 13, no. 1, pp. 70-75, Mar. 1998.
  8. L. Xu, X. Ruan, C. Mao, B. Zhang, and Y. Luo, "An improved optimal sizing method for wind-solar-battery hybrid power system," IEEE Trans. Sustainable Energy., vol. 4, no. 3, pp. 774785, Jul. 2013.
  9. B. S. Borowy and Z. M. Salameh,"Dynamic response of a stand-alone wind energy conversion system with battery energy storage to a wind gust,"IEEE Trans. Energy Convers., vol. 12, no. 1, pp. 73-78, Mar. 1997.
  10. S. Bae and A. Kwasinski, "Dynamic modeling and operation strategy for a microgrid with wind and photovoltaic resources," IEEE Trans. Smart Grid, vol. 3, no. 4, pp. 1867-1876, Dec. 2012.
  11. C. W. Chen, C. Y. Liao, K. H. Chen and Y. M. Chen, "Modeling and controller design of a semi isolated multi input converter for a hybrid PV/wind power charger system," IEEE Trans. Power Electron., vol. 30, no. 9, pp. 4843-4853, Sept. 2015.

Downloads

Published

2018-02-28

Issue

Section

Research Articles

How to Cite

[1]
Prasanna Lakshmi Bukke , " ON-Grid Hybrid Multi-Input Transformer Coupled Bidirectional DC-DC Converter with Multilevel Inverter , International Journal of Scientific Research in Science, Engineering and Technology(IJSRSET), Print ISSN : 2395-1990, Online ISSN : 2394-4099, Volume 1, Issue 3, pp.379-385, May-June-2015.