Rapid Magnetic Resonance Imaging Using Undersampled Projection-Onto-Convex-Sets Reconstruction

Authors

  • Mohammad Sabati  Department of Electrical Engineering, Australian College of Kuwait, West Mishref, Kuwait Department of Radiology, Miller School of Medicine, University of Miami, Miami, FL, USA
  • Leila Borvayeh  Department of Mathematics, Australian College of Kuwait, West Mishref, Kuwait

Keywords:

MRI, Image Reconstruction, Rapid MRI Data Acquisition, POCS, Parallel Imaging

Abstract

Scan time reduction is important in clinical magnetic resonance imaging (MRI). Partial Fourier data acquisitions rely on the conjugate symmetry of Hermitian data, allowing for shorter scan times due to fewer phase-encoding steps needed during the MRI data acquisition. Estimation of the missing k-space MR data is then usually accomplished by direct conjugate synthesis (e.g., homodyne reconstruction) or by iterative constraint-based algorithms (e.g., projection-onto-convex sets, POCS). Faster image acquisition has been achieved by combining partial Fourier acquisitions with parallel MRI. In this study, an iterative partial Fourier reconstruction method based on POCS technique is presented for sharply decreasing MRI scan times. It is achieved by asymmetrically undersampling k-space MR data acquired using a multi-element MRI receive coil. The results obtained from experimental models (phantoms) and humans shows that the proposed method can rapidly produce high-quality MR images with high acceleration rates.

References

  1. Carlson JW. "An algorithm for NMR imaging reconstruction based on multiple RF receiver coils". J Magn Reson 1987; 74:376-380.
  2. Hutchinson M, Raff U. "Fast MRI data acquisition using multiple detectors". Magn Reson Med 1988; 6(1):87-91.
  3. Kwiat D, Einav S, Navon G. "A decoupled coil detector array for fast image acquisition in magnetic resonance imaging". Med Phys 1991; 18(2):251-65.
  4. Hollingsworth KG. "Reducing acquisition time in clinical MRI by data undersampling and compressed sensing reconstruction". Phys Med Biol. 2015 Nov 7;60(21):R297-322.
  5. Chu ML, Chang HC, Chung HW, Truong TK, Bashir MR, Chen NK. "POCS-based reconstruction of multiplexed sensitivity encoded MRI (POCSMUSE): A general algorithm for reducing motion-related artifacts". Magn Reson Med. 2015 Nov;74(5):1336-48.
  6. Ra JB, Rim CY. "Fast imaging using subencoding data sets from multiple detectors". Magn Reson Med 1993; 30(1):142-5.
  7. Sodickson DK, Manning WJ. "Simultaneous acquisition of spatial harmonics (SMASH): fast imaging with radiofrequency coil arrays". Magn Reson Med 1997; 38(4):591-603.
  8. Fritz J, Fritz B, Zhang J, Thawait GK, Joshi DH, Pan L, Wang D. "Simultaneous Multislice Accelerated Turbo Spin Echo Magnetic Resonance Imaging: Comparison and Combination with In-Plane Parallel Imaging Acceleration for High-Resolution Magnetic Resonance Imaging of the Knee". Invest Radiol. 2017 Sep;52(9):529-537
  9. Sodickson DK. "Tailored SMASH image reconstructions for robust in vivo parallel MR imaging". Magn. Reson. Med. 2000; 44:243-251.
  10. Poser BA, Setsompop K. "Pulse sequences and parallel imaging for high spatiotemporal resolution MRI at ultra-high field". Neuroimage. 2017 Apr 6. pii: S1053-8119(17)30295-1.
  11. Bydder M, Larkman DJ, Hajnal JV. "Generalized SMASH imaging". Magn Reson Med 2002; 47(1):160-70.
  12. Pruessmann KP, Weiger M, Scheidegger MB, Boesiger P. "SENSE: Sensitivity encoding for fast MRI". Magn Reson Med 1999; 42(5):952-962.
  13. Pruessmann KP, Weiger M, Bornert P, Boesiger P. "Advances in sensitivity encoding with arbitrary k-space trajectories". Magn Reson Med 2001; 46(4):638-51.
  14. Weiger M, Pruessmann KP, Boesiger P. "2D SENSE for faster 3D MRI". MAGMA. 2002; 14(1):10-9.
  15. Larkman DJ, Hajnal JV, Herlihy AH, Coutts GA, Young IR, Ehnholm G. "Use of multicoil arrays for separation of signal from multiple slices simultaneously excited". J Magn Reson Imaging. 2001; 13(2):313-7.
  16. Griswold MA, Jakob PM, Heidemann RM, Nittka M, Jellus V, Wang J, Kiefer B, Haase A. "Generalized autocalibrating partially parallel acquisitions (GRAPPA)". Magn Reson Med. 2002; 47(6):1202-10.
  17. Jakob PM, Griswold MA, Edelman RR, Sodickson DK. "AUTO-SMASH: a self-calibrating technique for SMASH imaging". MAGMA 1998; 7:42-54.
  18. Heidemann RM, Griswold MA, Haase A, et al. "VD AUTO-SMASH imaging" Magn Reson Med 2001;45(6):1066-74.
  19. Wang J, Kluge T, Nittka M, et al. Parallel acquisition techniques with modified SENSE reconstruction mSENSE." Proceedings of the First Wu¨rzburg Workshop on Parallel Imaging Basics and Clinical Applications, Wu¨rzburg, Germany, 2001:89.
  20. Griswold MA, Jakob PM, Nittka M, et al. "Partially parallel imaging with localized sensitivities (PILS)". Magn Reson Med. 2000;44:602–609.
  21. Kyriakos WE, Panych LP, Kacher DF, et al. "Sensitivity profiles from an array of coils for encoding and reconstruction in parallel (SPACE RIP)". Magn Reson Med. 2000; 44:301–308.
  22. Liang Z-P, Boada FE, Constable RT, Haacke EM, Lauterbur PC, Smith MR. "Constrained reconstruction methods in MR imaging". Rev Magn Reson Med 1992;4:67–185.
  23. Feinberg DA, Hale JD, Watts JC, Kaufman L, Mark A. "Halving MR imaging time by conjugation: demonstration at 3.5 kG". Radiology 1986;161:527– 31.
  24. Haacke EM, Mitchell J, Lee D. "Improved contrast at 1.5 Tesla using half-Fourier imaging: application to spin-echo and angiographic imaging". Magn Reson Imaging 1990;8:79– 90.
  25. Bernstein MA, Fain SB, Riederer SJ. "Effect of windowing and zerofilled reconstruction of MRI data on spatial resolution and acquisition strategy". J Magn Reson Imaging 2001;14:270– 80.
  26. Noll DC, Nishimura DG, Macovski A. "Homodyne detection in magnetic resonance imaging". IEEE Trans Med Imaging 1991;10: 154–63.
  27. Haacke EM, Lindskog ED, Lin W. "A fast, iterative partial Fourier technique capable of local phase recovery". J Magn Reson 1991;92: 126–45.
  28. Peng H, Sabati M, Lauzon ML, Frayne R. "MR Image Reconstruction of Sparsely Sampled 3D k-Space Data by Projection-onto-Convex Sets". Magn Reson Imaging, vol 24, 2006, pp. 761-773.
  29. Samsonov AA, Kholmovski EG, Parker DL, Johnson CR. POCSENSE: POCS-based reconstruction for sensitivity encoded magnetic resonance imaging. Magn Reson Med 2004; 52: 1397-1406.
  30. Sabati M, Borvayeh L. "Highly Accelerated MRI Using Undersampled POCS Reconstruction". Proceedings of the 38th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, p. FrCT6.28, 17-20 August 2016, Orlando, FL, USA.
  31. Sabati M, Peng H, Lauzon ML, Frayne R. "A Statistical Method for Characterizing the Noise in Nonlinearly Reconstructed Images from Undersampled MR Data: The POCS Example", Magn Reson Imaging. 2013 Nov; 31(9):1587-98.
  32. Sayin O, Saybasili H, Zviman MM, Griswold M, Halperin H, Seiberlich N, Herzka DA. "Real-time free breathing cardiac imaging with self-calibrated through-time radial GRAPPA". Magn Reson Med. 2017 Jan;77(1):250-264.

Downloads

Published

2017-10-31

Issue

Section

Research Articles

How to Cite

[1]
Mohammad Sabati, Leila Borvayeh, " Rapid Magnetic Resonance Imaging Using Undersampled Projection-Onto-Convex-Sets Reconstruction, International Journal of Scientific Research in Science, Engineering and Technology(IJSRSET), Print ISSN : 2395-1990, Online ISSN : 2394-4099, Volume 3, Issue 6, pp.704-709, September-October-2017.