Evaluation of Suitability of Dampers in different Soil Condition for Multi Storey Buildings under Seismic Conditions

Authors

  • Faria Aseem  Assistant Professor, Department of Civil Engineering, Lords Institute of Engineering and Technology, Hyderabad, Andhra Pradesh, India
  • N. Harika Priya  Assistant Professor, Department of Civil Engineering, Lords Institute of Engineering and Technology, Hyderabad, Andhra Pradesh, India

Keywords:

E-TABS, Dampers, seismic load, Storey displacement, storey shear, storey drift, building drift and base shear.

Abstract

We are living in the age of multi storey building due to fast urban development where everyone want to live in the city centre to avail all comfort and accessibility to all facilities needed for daily to day life which resulted in huge demand of high rise and multi storey buildings. Engineers need to find out the different structural arrangements to provide robust design to withstand the earthquake which are common now a d Now-a-days without compromising the occupants comforts. Earthquake cause heavy deflections of the building even if it is design to withstand the earthquake forces safely which cause great discomfort and fear to the occupants in addition to the damage to the finishes and cladding/glazing of the buildings. I order to eliminate large displacement ill effects without designing the stiff building structure which may greater forces at base in terms of base share, dampers has been introduces in the high rise construction industry. This paper is the outcome of the structural analysis study conducted on 13 storey building models to compare the effects of utilizing dampers on building drifts using E-TABS software. After detailed analysis and comparison using E-TABS software it is concluded that the building with dampers performs better under seismic load conditions than the building without dampers under the same loadings and dampers effectively works to reduce to building drifts under seismic loading conditions.

References

  1. Analysis and design of a multi storey building with shear walls in different position , M. Tech. thesis by Ashwini
  2. G. Anshumn. S, Dipendu Bhunia, and Bhavin Rmjiyani (2011), “Solution of shear wall location in Multi-storey building." International Journal of Civil Engineering, Vol. 9, No.2Pages 493-506
  3. M. Asharaf, Z. A. Siddiqi and M. A. Javed, “Configuration of Multi-storey building subject to lateral forces". Asian Journal of Civil Engineering (Building & Housing), Vol. 9.
  4. I Quanfeng Wang, Lingyun Wang, Qiangsheng Liu “Effect of shear wall height an earthquake response" Engineering Structures 23 (2001).
  5. IS: 1893 (Part 1) 2002- Indian standard- “Criteria for earthquake resistant design of structures", Bureau of Indian Standards, New Delhi
  6. Chen Qin and Qian Jiaru.2002. “Static inelastic analysis of RC shear walls", department of civil engineering, Tsinghua University, Beijing 100084, China
  7. Ji Dongyu, Li Xiaofen, "Seismic behavior analysis of high rise connected structures," MEIC- Engineering Structures, 2008, 30 (11): 3219-3227
  8. Alalper Turan, Sean D and hinchberger A, “seismic soil-structure interaction in buildings of stiff clay with embedded basement store
  9. Mengke Li, Xiao La, xinzheng Lu and leaping ye. “Influence of soil–structure interaction on seismic collapse resistance of super-tall buildings".

Downloads

Published

2017-10-31

Issue

Section

Research Articles

How to Cite

[1]
Faria Aseem, N. Harika Priya, " Evaluation of Suitability of Dampers in different Soil Condition for Multi Storey Buildings under Seismic Conditions, International Journal of Scientific Research in Science, Engineering and Technology(IJSRSET), Print ISSN : 2395-1990, Online ISSN : 2394-4099, Volume 3, Issue 6, pp.787-795, September-October-2017.