Harmonic Mitigation using D-STATCOM with Renewable Energy Sources for improved Power Quality using Intelligent Controller
Keywords:
Diesel Generator, D-STATCOM, MPPT, Power Quality, hysteresis current controller (HCC), total harmonic distortion (THD), Wind Generating System (WGS).Abstract
In this paper, distribution static compensator is used to compensate the source currents which are affected by the harmonics due to unbalanced and non-linear loads. Here a PV based inverter is used as a shunt active power filter to mitigate the current harmonics. The theory of unit vector control is used to generate the three phase reference currents. Hysteresis current controller (HCC) is used to generate the switching pulses for the gate drives of the grid interfacing inverter. The inverter act as a shunt active power filters to inject the compensated current to the system. The total harmonic distortion (THDs) of the source currents are reduced by using D-STATCOM. The THDs of the distribution system with and without are compared. Further the paper discuss about Fuzzy logic controller and impact of controller on power quality. By replacing PI with Fuzzy we can compare the THD of source current and observed that fuzzy is having better performance than PI. The whole work is been done in MATLAB/SIMULINK.
References
- K. Bala Nikilesh, P. Nageswara Rao' Harmonic Compensation using D-STATCOM in Combination with Renewable Energy Sources to
- Enhance Power Quality' 978-1-4799-7678-2/15/$31.00 2015 IEEE
- Mukhtiar Singh, Student Member, IEEE, Vinod Khadkikar, Member, IEEE, Ambrish Chandra, Senior Member, IEEE and Rajiv K. Varma, Senior Member, lEEE "Grid Interconnection of Renewable Energy Sources at the Distribution Level With Power-Quality Improvement Features."IEEE Transactions On Power
- U. Borup, F. Blaabjerg, and P. N. Enjeti, "Sharing of nonlinear load in parallel-connected three-phase converters," IEEE Trans. Ind. Appl., vol. 37, no. 6, pp. 1817-1823, Nov.Dec. 2001.
- J. H. R. Enslin and P. J. M. Heskes, -Hannonic interaction between a large number of distributed power inverters and the distribution network, l IEEE Trans. Power Electron., vol. 19, no. 6, pp. 1586-1593, Nov. 2004.
- P. Pinto, R. Pregitzer, L. F. C. Monteiro, and 1. L. Afonso, "3-phase 4-wire shunt active power filter with renewable energy interface," presented at the Conf. IEEE Rnewable Energy & Power Quality, Seville, Spain, 2007.
- J. M. Guerrero, L. G. de Vicuna, J. Matas, M. Castilla, and J. Miret, "A wireless controller to enhance dynamic perfonnance of parallel inverters in distributed generation systems," IEEE Trans. Power Electron., vol. 19, no. 5, pp. 1205-1213, Sep. 2004.
- Karuppanan P ,Kamala KantaMahapatrab-PLL Synchronization With PID Controller Based on Shunt Active Power Line FILTER.I International Journal of Computer and Electrical Engineering,VoI.3,No.l,February 2011.
- M. Aiello, A. Catalioti, S. Favuzza, G. Graditi, -Theoretical and Experimental Comparison of Total Harmonic Distortion Factors for the evaluation of Harmonic and Inter harmonic Pollution of Grid Connected."IEEE Transactions on Power Delivery, Vol. 21, No. 3, July 2006.
- I. M. A. Myrzik, and M. Calais, Member, IEEE -String and Module Integrated Inverters for Single-Phase Grid Connected Photovoltaic Systems - A Reviewll. Power Technical Conference Proceedings, 2003 IEEE Bologna.
Downloads
Published
Issue
Section
License
Copyright (c) IJSRSET

This work is licensed under a Creative Commons Attribution 4.0 International License.