A Noval Implementation of Microcontroller Based Dvr for Industrial Application
Keywords:
Dynamic voltage restorer(DVR), voltage mitigation, power quality issues, transformer-less dynamic voltage restorer(TDVR), Predictive voltage control scheme.Abstract
In this study, a new topology for dynamic voltage restorer (DVR) has been proposed. The topology is inspired by the buck-boost converter to produce the required compensation voltage. This topology is able to compensate different voltage disturbances such as transients, sag, swell and flicker without leap of the phase angle. The mass of the proposed topology has been reduced due to lack of injection topology. In addition to, the required compensation energy is directly delivered from the gridthrough the grid voltage.In an Electrical industry, Power quality is primarily a main concern. The power quality issue occurs when the system load in the power system is affected with problems such as transients, sag, swell and flicker. Hence the power quality issues needed to be tackled. In the Distribution side, Major power quality issue which causes disturbance in the system is due to the voltage sag and swell hence it is needed be eliminated from the system.
References
- Hietpas, S.M., Naden, M.: 'Automatic voltage regulator using an AC voltage-voltageconverter',IEEETrans.Ind. Appl.,2000, 36,(1), pp. 33–38
- Vilathgamuwa, D.M., Member, S., Perera, A.A.D.R., et al.: 'Dynamic voltage restorer', 2003, 18, (3), pp. 928–936
- Wijekoon, H.M., Vilathgamuwa, D.M., Choi, S.S.: 'Interline dynamic voltage restorer: an economical way to improve interline power quality', IEE Proc. Gener.Transm. Distrib.,2003, 150, (5), pp. 513–520
- Wang, B., Member, S., Venkataramanan, G., et al.: 'Operation and control of a dynamic voltage restorer using transformer coupled H-bridge converters', 2006, 21, (4), pp. 1053–1061
- Babaei, E., FarhadiKangarlu, M.: 'Voltage quality improvement by a dynamic voltage restorer based on a direct three-phase converter with fictitious DC link', IET Gener. Transm. Distrib., 2011, 5, (8), p. 814
- Babaei, E., Kangarlu, M.F.: 'Sensitive load voltage compensation against voltage sags/swells and harmonics in the grid voltage and limit downstream fault currents using DVR', Electr. Power Syst. Res., 2012, 83, (1), pp. 80–90
- Jacobson, D.A., Member, S.: 'A novel configuration for a cascade inverter-based storage requirements', IEEE Trans. Power Deliv., 2008, 23, (2), pp.881–888
- Babaei, E.: 'Control of direct three-phase to single-phase converters under balanced and unbalanced operations', Energy Convers. Manag., 2011, 52, (1), pp. 66–74
- Lozano-Garcia, J.M., Ramirez, J.M.: 'Voltage compensator based on a direct matrix converter without energy storage', IET Power Electron., 2015, 8, (3), pp. 321–332
- Babaei, E., FarhadiKangarlu, M.: 'Cross-phase voltage sag compensator for three-phase distribution systems', Int. J. Electr. Power Energy Syst.,2013, 51, pp. 119–126
- Babaei, E., Kangarlu, M.F., Sabahi, M.: 'Compensation of voltage disturbances in distribution systems using single-phase dynamic voltage restorer', Electr. Power Syst. Res., 2010, 80, (12), pp. 1413–1420
- Babaei, E., FarhadiKangarlu, M.: 'Operation and control of dynamic voltage restorer using single-phase direct converter', Energy Convers. Manag., 2011, 52, (8–9), pp. 2965–2972
- Kaniewski, J., Fedyczak, Z., Benysek, G.: 'AC voltage sag/swell compensator based on three-phase hybrid transformer with buck-boost matrix-reactance chopper', IEEE Trans. Ind. Electron., 2014, 61, (8), pp. 3835–3846
Downloads
Published
Issue
Section
License
Copyright (c) IJSRSET

This work is licensed under a Creative Commons Attribution 4.0 International License.