In Phase Compensation of Sag and Swell Voltage by using Dynamic Voltage Restorer

Authors

  • Diksha Wasnik  P.G Schiolar, Tulsiramji Gaikwad Patil College of Engineering And Technology Nagpur, India
  • Prof. Radharaman Shaha  Assistant Professor and HOD, Electrical Engineering, Tulsiramji Gaikwad Patil College of Engineering and Technology Nagpur, Maharashtra, India

DOI:

https://doi.org//10.32628/IJSRSET19628

Keywords:

DVR, voltage sag, voltage swell, In Phase compensation, Battery Energy storage ,SRF controller

Abstract

Today most of the industries and customers are using sensitive and sophisticated electrical equipment based on semiconductor devices, these may causes power quality disturbance. The major problems are voltage sag and swell. The sag and swell not only occur by disturbed power quality but also due to high system tapping at point of common coupling. To overcome this problem and to improve power quality the distribution companies uses various custom power devices. Among the various custom power devices Dynamic voltage restorer is used for compensation in this paper, which is most popular and widely used method. Here, In phase compensation technique of DVR is used with battery energy storage system. The voltage at PCC have been observed. The control technique employed here is SRF theory with PI controller. The overall work is carried out in MATLAB Simulink.

References

  1. Riddhi Pandya, Falguni Bhavsar, “Study On Compensation Of Voltage Sag And Voltage Swell By Using DVR”, Proceeding IEEE International Conference On Current Trends Towards Converging Technologies, Coimbatore , India, 2018
  2. Mr. Jackson Prajapati , Patel Jalpa S ,Pradhan Mamini S,Thakkar Unnati R, “Power Quality Improvement Using Dynamic Voltage Restorer (DVR)”, International Research Journal Of Engineering And Technology Irjet,Apr 2017
  3. Suresh Palla , Keerthi Sandela , B.Sai Ramya, “Voltage Sag And Swell Compensation Using DVR To Enhance Power Quality” , IOSR-JEEE, PP 17-26, March –Apr 2017
  4. S,R. Reddy , P.V Prasad And G.N.Srinivas, “ Balanced Voltage Sag And Swell Compensation By Using Dynamic Voltage Restorer” , 1st IEEE International Conference On Power Electronics, Intelligent Control And Energy System ,2016
  5. Miss Akanksha V. Ital, Prof.Sumit A. Borkhade, “Compensation Of Voltage Sags And Swell By Using Dynamic Voltage Restorer(DVR)” , International Conference On Electrical , Electronics And Optimization Technique(ICEEOT) , IEEE, 2016
  6. Prof.Amol Dhanbhar, Prof.Ashish Bhopale ,Prof Sagar Bole, “Compensation Of Voltage Sag And Swell Using DVR” , ICSTSD,2016
  7. Dhivya T. “Implementation Of DVR In Distribution System”, International Journal Of Science And Research , Issue 5, Volume 04 , May 2015
  8. Ram Hemantkumar Mistry, Prof Hemin Motiwal, “Elective Control Strategy To Enhance Power Quality Improvement Using DVR” , International Journal Of Engineering Development Research, Issue 2,Volume , 2014
  9. Ram Hemantkumar Mistry, Prof Hemin Motiwal, “ Effective Control Strategy To Enhance Power Quality Improvement Using DVR” International Journal Of Engineering Development And Research IJEDR, Issue2 ,Volume 2, 2014
  10. M. Swathi Priya , Dr.T.Venkatesan, “ Adynamic Voltage Restorer With Voltage Sag Compensation At Medium Voltage Level Using PI Control Scheme” , IJAREEIE,Issue 2, Vol.3, Feb.201
  11. V.Jayalakshmi, Dr.N.O.Gunasekar, “Implementaion Of Discrete Pwm Control Scheme On Dynamic Voltage Restorer For Mitigation Of Voltage Sag And Swell” ,IEEE,2013
  12. Uppunoori Venkata Reddy, Chandra Babu, S.S.Dash, “Space Vector Pulse Width Modulation Based DVR To Mitigate Voltage Sag And Swell”, International Conference On Computer Communication And Informatics, IEEE, Coimbaore India, 04-06 Jan, 2013
  13. Ravilla Madhusudan ,G.Ramamohan Rao, “Modelling And Simulation Of D-Statcom For Power Quality Problem Voltage Sag And Swell Based On Sinusoidal Pwm”, IEEE International Conference On Advances In Engg, Science And Management, March 30-31 2012
  14. S.F.Torabi, D.Nazarpour, Y.Shayestefard,“ Compensation Of Sag And Swell Voltage Using DVR During Single Line To Ground And Three Phase Fault”, International Journal On Technical And Physical Problem Of Engineering, IJTPE, Issue 12,Volume 04 No.03, Pp.126-132, Sep.2012
  15. D Rajasekaran ,Dr.Subransu Sekar Dash, P Vignesh , “Mitigation Of Voltage Sag And Swell By DVR” , Proc. Of International Conference On Advances In Recent Technologies In Communication And Computing, IET,2011
  16. P. Meena , K Uma Rao, Ravishankar D, “ A Modified Algoritham For Detection Of Voltage Sag And Swell In Practical loads, 3rd international conference on power system, kharagpur,India, IEEE, Dec 27-29 2009

Downloads

Published

2019-04-30

Issue

Section

Research Articles

How to Cite

[1]
Diksha Wasnik, Prof. Radharaman Shaha, " In Phase Compensation of Sag and Swell Voltage by using Dynamic Voltage Restorer, International Journal of Scientific Research in Science, Engineering and Technology(IJSRSET), Print ISSN : 2395-1990, Online ISSN : 2394-4099, Volume 6, Issue 2, pp.77-83, March-April-2019. Available at doi : https://doi.org/10.32628/IJSRSET19628