Doctors Assistive System Using Augmented Reality to Enhance Medical Operations

Authors

  • K. Gowri  Assistant Professor, Department of Electrical and Electronics Engineering, RAAK College of Engineering & Technology, Puducherry, India
  • D. Branan  UG Scholar, Department of Electrical and Electronics Engineering, RAAK College of Engineering & Technology, Puducherry, India
  • A. Nirmal George  UG Scholar, Department of Electrical and Electronics Engineering, RAAK College of Engineering & Technology, Puducherry, India
  • M. Kavimani  
  • S. Veda  

Keywords:

Augmented Reality (AR), PIC Microcontroller, heartbeat sensor, temperature sensor, respiratory sensor, Lora transmitter

Abstract

Surgeons are regularly on the lookout for technologies that will enhance their operating environment. They are often the early adopters of technologies that allow their field to offer a better surgical and patient experience. The continuing enhancement of the surgical environment in the digital age has led to a number of innovations being highlighted as potential disruptive technologies in the surgical workplace. Augmented reality (AR) is rapidly becoming increasingly available, Augmented reality (AR) is a promising tool to conveniently provide needed information and may thus overcome the limitations of existing approaches. To this end, a prototypical AR application was developed to guide the insertion of needles to spinal targets using the mixed-reality glasses Microsoft HoloLens. The system’s registration accuracy was attempted to measure and three guidance visualization concepts were evaluated concerning achievable in-plane and out-of-plane needle orientation errors in a comparison study. Results suggested high registration accuracy and showed that the AR prototype is suitable for reducing out-of-plane orientation errors. AR is the addition of artificial information to one or more of the senses that allow the user to perform tasks more efficiently. We propose a system in which important information for the doctors is displayed on semi-transparent glasses included in an AR headset and therefore are mixed with the real-world view

References

  1. Lewin J.S., Thomas C., Pereira P.L., ET AL.: ‘Freehand real-time MRI-guided lumbar spinal injection procedures at 1.5 T: feasibility, accuracy, and safety’, Am. J. Roentgenol., 2009, 192, (4), pp. W161–W167
  2. Lauda F.L.G., De Camargo M.F., Lauda F.V.: ‘Evaluation of facet, sacral and foraminal infiltrations in the treatment of low back pain’, Coluna/Columna, 2017, 16, (2), pp. 153–168
  3. Krombach G.A., Schmitz-Rode T., Wein B.B., ET AL.: ‘Potential of a new laser target system for percutaneous CT-guided nerve blocks: technical note’, Neuroradiology, 2000, 42, (11), pp. 838–841
  4. Oliveira-Santos T., Klaeser B., Weitzel T., ET AL.: ‘A navigation system for percutaneous needle interventions based on PET/CT images: design, workflow and error analysis of soft tissue and bone punctures’, Comput. Aided Surg., 2011, 16, (5), pp. 203–219
  5. Engstrand J., Toporek G., Harbut P., ET AL.: ‘Stereotactic CT-guided percutaneous microwave ablation of liver tumors with the use of high-frequency jet ventilation: an accuracy and procedural safety study’, Am. J. Roentgenol., 2017, 208, (1), pp. 193–200

Downloads

Published

2023-04-30

Issue

Section

Research Articles

How to Cite

[1]
K. Gowri, D. Branan, A. Nirmal George, M. Kavimani, S. Veda "Doctors Assistive System Using Augmented Reality to Enhance Medical Operations" International Journal of Scientific Research in Science, Engineering and Technology (IJSRSET), Print ISSN : 2395-1990, Online ISSN : 2394-4099, Volume 10, Issue 2, pp.660-664, March-April-2023.