Experimental Analysis of Earth Air Heat Exchanger (EAHE) Systems in Different Laying Arrangements

Authors

  • Golu Dadhore  Kailash Narayan Patidar college of Technology, Research Scholar, RGPV Bhopal, Madhya Pradesh, India
  • Er. Priyank Dixit  Kailash Narayan Patidar college of Technology, Research Scholar, RGPV Bhopal, Madhya Pradesh, India

Keywords:

Earth Air Heat Exchanger, COP, Nusselt Number, Reynolds Number, Thermal Comfort.

Abstract

The present world energy scenario indicates that the conventional energy sources are depleting and per capita energy consumption is indication of living standard of a nation so, it becomes very important to find and explore nonconventional energy sources to meet the energy requirement of the society. The nonconventional energy sources are better option of clean and sustainable energy. This kind of energy is, at principle, inexhaustible and can be found and exploited equally well on the planet. The increased need for thermal comfort, the rising cost of energy consumption and environmental issues have made alternative and hybrid techniques and methods very attractive. Earth tubes, also called earth- air heat exchangers (EAHX) offer the possibility of reducing use of nonrenewable energy in ventilation and air conditioning systems and provide good indoor air quality for the conditioned environments. The following conclusion is made on the basis of experimental investigation done on Earth Air Heat Exchanger: The average Temperature rise from inlet to outlet is from 3 to 7°C in both series and parallel arrangements,Nusselt Number in parallel connection for different Reynolds Number is higher than the Nusselt number in series connection,Nusselt number in parallel connection varies from (19 to 24 ) and ( 18 to 22 ) in series connection, COP of the parallel connection is higher than the COP of series for the Reynolds number greater than 30000.

References

  1. Bansal Vikas, Misra Rohitm, Agrawal Ghanshyam Das, Mathur Jyotirmay. Performance analysis of earth-pipe air heat exchanger for winter heating. Enegry and Building 2009; 41:1151-4.
  2. Bansal Vikas, Misra Rohitm, Agrawal Ghanshyam Das, Mathur Jyotirmay. Performance analysis of earth-pipe air heat exchanger for summer cooling. Enegry and Building 2010; 42:645-8.
  3. Bansal NK, Sodha MS. Bhardwaj SS. Performance of earth-air tunnel system. Energy Research 1983; 7(4):333-41.
  4. Manoj kumar Dubey, Dr. J.L.Bhagoria, Dr. Atul lanjewar , Earth Air Heat Exchanger in Parallel Connection
  5. Santamouris, A. Argiriou, M. Vallindras, Design and operation of a low energy consumption passive solar agriculture greenhouse, Solar Energy 52 (1994) 371-378.
  6. Tombazis, A Argirion, M. Santamouris, Performance evaluation of passive and hybrid cooling components for a hotel complex, International Journal of Solar Energy 9 (9) (1990) 1-12.

Downloads

Published

2016-12-31

Issue

Section

Research Articles

How to Cite

[1]
Golu Dadhore, Er. Priyank Dixit, " Experimental Analysis of Earth Air Heat Exchanger (EAHE) Systems in Different Laying Arrangements, International Journal of Scientific Research in Science, Engineering and Technology(IJSRSET), Print ISSN : 2395-1990, Online ISSN : 2394-4099, Volume 2, Issue 6, pp.663-670, November-December-2016.