Effect of No - load and Load Condition on Transformer Sound

Authors

  • Dr. Hitesh Paghadar  Associate Professor, Electrical Engineering Department, OM Engineering College, Junagadh, Gujarat, India

DOI:

https://doi.org//10.32628/IJSRSET184113

Keywords:

Transformer Sound, Load sound, No-load Sound, Measurement Scale

Abstract

Increasing environment noise pollution is a matter of great concern and of late has been attracting public attention. Sound produces the minute oscillatory changes in air pressure and is audible to the human ear when in the frequency range of 20Hz to 20 kHz. The chief sources of audible sound are the magnetic circuit of transformer which produces sound due to magnetostriction phenomenon, vibration of windings, tank and other structural parts, and the noise produced by cooling equipments. This paper presents the validation for sound level measurement scale, why A-weighted scale is accepted for sound level measurement, experimental study carried out on 10MVA Power Transformer. Also presents the outcomes of comparison between No-Load sound & Load sound level measurement, experimental study carried out on different transformer like - 10MVA, 50MVA, 100MVA Power Transformer, to define the dominant factor of transformer sound generation.

References

  1. Martin J. Heathcote, A. C. Franklin, “Operation and Maintenance” 13th ed., The J and P transformer, Elsevier Ltd. 2007, pp 430-453.
  2. India. Govt. Rule, “Ministry of Environment and Forest Notification”, New Delhi, 14-Feb., 2000.
  3. International standard IEC 60076-10, “Power transformers determination of sound levels”, 1st ed., 2001-05.
  4. Bernard Hochart, “Power Transformer Handbook”, Alsthom Transformer Division, Saint-Ouen, France, 1987.
  5. www.engineeringtoolbox.com
  6. EMCO Inhouse Handbook, “Know your transformers”, EMCO Ltd. -Thane, May-2007.
  7. Matshediso Phoshoko, “Power transformer noise: sources, factors and remedies”, Powertech Transformer Ltd., Aug. 2013.
  8. S.V.Kulkarni, S.A.Khaparde, “Transformer Noise in Tansformer Engineering Design”, 2nd ed., Technology & Diagnostics, CRC press, 2013.
  9. Abdel-Fattah. A. MAHMOUD, Hany A. SHAWKY, 2016, Noise Measurement and Analysis of the Power Transformer, Romanian Journal of Acoustics and Vibration (January-2016), A publication of the Romanian Society of Acoustics, ISSN 1584- 7284, vol XIII.
  10. National Electrical Manufacturers Association (NEMA) Standard, Transformers, Regulators and Reactor Publication No. TR-1, 1993.
  11. Central Board of Irrigation and Power (CBIP), Manual on Transformers Publication No.-295, March 2006.
  12. Reiplinger E., “Study of Noise Emitted by Power Transformers based on Todays viewpoint”, CIGRE, Paris-Bericht/rapport 12-08, 1988.
  13. Abhinavkumar, 2013, “Causes of noise generation & its mitigation in Transformer”, Journal of Environmental science and Engineering & Technology (2013), vol.2, pp. 75-79.

Downloads

Published

2018-11-30

Issue

Section

Research Articles

How to Cite

[1]
Dr. Hitesh Paghadar, " Effect of No - load and Load Condition on Transformer Sound, International Journal of Scientific Research in Science, Engineering and Technology(IJSRSET), Print ISSN : 2395-1990, Online ISSN : 2394-4099, Volume 4, Issue 11, pp.11-15, November-December-2018. Available at doi : https://doi.org/10.32628/IJSRSET184113