Automatic Fault Detection of Transmission Line Using IOT

Authors

  • M. S. Lagad HSBPVT'S GOI Faculty of Engineering, Kashti, Maharashtra, India Author
  • S. S. Shinde HSBPVT'S GOI Faculty of Engineering, Kashti, Maharashtra, India Author
  • P. D. Lashkare HSBPVT'S GOI Faculty of Engineering, Kashti, Maharashtra, India Author
  • Y. R. Bagale HSBPVT'S GOI Faculty of Engineering, Kashti, Maharashtra, India Author
  • Prof. H. S. Avchat Assistant Professor, HSBPVT'S GOI Faculty of Engineering, Kashti, Maharashtra, India Author

Keywords:

Current sensor, Node MCU, Internet Of Thing

Abstract

The development and advance in technology, many things are changes. The technology laid out to understand its importance like in urban areas, the electrical Line to go Transmission instead of overhead lines, which grab less space and is consider as the effective and efficient way of transmission. But the problem ascends when any fault be occurred in the Transmission Line and it's also difficult to detect the proper location of the fault during the process of repairing that especial Line and the methods existed till now follows some algorithm in order to scan the location of the fault. The raised system which constitute of current sensors, microcontroller (Node MCU) and Wi-Fi modem which creates a course between the combined hardware and internet so that the real time data can be successively communicated towards server its being successively communicate with towards server and along with this everything becomes smart and interconnected with the help of IoT (internet of things) those are real time data can be retrieved in pc or mobile phones from the server. Hitherward by using useful stage provided by IoT any one can recover information whenever they are necessary. By implementing the proposed system life of the Line will also get by grown because after implementing the system the supply transmission of the power can be closed till the fault gets mend and through this the inessential losses which are developed though the leakage of current can be avoided.

Downloads

Download data is not yet available.

References

S. T. Senini and P. J. Wolfs, “Systematic identification and review of hybrid active filter topologies”, in Proc. IEEE 33rd Annu.Power Electron. Spec. Conf., 2002, vol. 1, pp. 394–399

P. Salmer´on and S. P. Litr´an “A control strategy for hybrid power filter to compensate four-wires threephase systems”, IEEE Trans. Power Electron., vol. 25, no. 7, pp. 1923–1931, Jul. 2010. [3] Luo, Z. K. Shuai, Z. J. Shen, W. J. Zhu, and X. Y. Xu, “Design considerations for maintaining dc-side voltage of hybrid active power filter with injection circuit”, IEEE Trans. Power Electron., vol. 24, no. 1, pp. 75–84, Jan. 2009.

H. Fujita and H. Akagi, “A practical approach to harmonic compensation in power systems: Series connection of passive and active filters”, IEEE Trans.

Ind. Appl., vol. 27, no. 6, pp. 1020–1025, Nov./Dec. 1991.

Z. Peng, H. Akagi, and A. Nabae, “A new approach to harmonic compensation in power systems: A combined system of shunt passive and series active filters”, IEEE Trans. Ind. Appl., vol. 26, no. 6, pp. 983– 990, Nov./Dec. 1990.

H.S.Avchat,M.S.Lagad,P.D.Lashkare,S.S.Shinde Y.R.Bagale "Automatic fault detection of transmission line using iot", International Journal of Scientific Research in Science, Engineering and Technology (IJSRSET), Online ISSN: 2394-4099, Print ISSN: 23951990, Volume 10 Issue 3, pp. 85-88, May June 2024. Journal URL: https://ijsrset.com/IJSRSET2310314

Downloads

Published

19-04-2024

Issue

Section

Research Articles

How to Cite

[1]
M. S. Lagad, S. S. Shinde, P. D. Lashkare, Y. R. Bagale, and Prof. H. S. Avchat, “Automatic Fault Detection of Transmission Line Using IOT ”, Int J Sci Res Sci Eng Technol, vol. 11, no. 2, pp. 342–345, Apr. 2024, Accessed: Nov. 21, 2024. [Online]. Available: https://ijsrset.com/index.php/home/article/view/IJSRSET2411251

Similar Articles

1-10 of 40

You may also start an advanced similarity search for this article.